Catalog

ArticleTitleManufacturer
3KXF421702V.A2.TFA.PSA.QZE.QM00Article: 3KXF421702V.A2.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A2.TFA.PSA.QZF.QM00Article: 3KXF421702V.A2.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A3.TFA.PSA.QZA.QM00Article: 3KXF421702V.A3.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A3.TFA.PSA.QZB.QM00Article: 3KXF421702V.A3.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A3.TFA.PSA.QZC.QM00Article: 3KXF421702V.A3.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A3.TFA.PSA.QZD.QM00Article: 3KXF421702V.A3.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A3.TFA.PSA.QZE.QM00Article: 3KXF421702V.A3.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421702V.A3.TFA.PSA.QZF.QM00Article: 3KXF421702V.A3.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 50; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V1.TFA.PSA.QZA.QM00Article: 3KXF421703V.V1.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V1.TFA.PSA.QZB.QM00Article: 3KXF421703V.V1.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V1.TFA.PSA.QZC.QM00Article: 3KXF421703V.V1.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V1.TFA.PSA.QZD.QM00Article: 3KXF421703V.V1.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V1.TFA.PSA.QZE.QM00Article: 3KXF421703V.V1.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V1.TFA.PSA.QZF.QM00Article: 3KXF421703V.V1.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V2.TFA.PSA.QZA.QM00Article: 3KXF421703V.V2.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V2.TFA.PSA.QZB.QM00Article: 3KXF421703V.V2.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V2.TFA.PSA.QZC.QM00Article: 3KXF421703V.V2.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V2.TFA.PSA.QZD.QM00Article: 3KXF421703V.V2.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V2.TFA.PSA.QZE.QM00Article: 3KXF421703V.V2.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.V2.TFA.PSA.QZF.QM00Article: 3KXF421703V.V2.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A1.TFA.PSA.QZA.QM00Article: 3KXF421703V.A1.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 20 mA, Alarm > 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A1.TFA.PSA.QZB.QM00Article: 3KXF421703V.A1.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 20 mA, Alarm > 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A1.TFA.PSA.QZC.QM00Article: 3KXF421703V.A1.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 20 mA, Alarm > 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A1.TFA.PSA.QZD.QM00Article: 3KXF421703V.A1.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 20 mA, Alarm > 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A1.TFA.PSA.QZE.QM00Article: 3KXF421703V.A1.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 20 mA, Alarm > 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A1.TFA.PSA.QZF.QM00Article: 3KXF421703V.A1.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 0 ... 20 mA, Alarm > 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A2.TFA.PSA.QZA.QM00Article: 3KXF421703V.A2.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A2.TFA.PSA.QZB.QM00Article: 3KXF421703V.A2.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A2.TFA.PSA.QZC.QM00Article: 3KXF421703V.A2.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A2.TFA.PSA.QZD.QM00Article: 3KXF421703V.A2.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A2.TFA.PSA.QZE.QM00Article: 3KXF421703V.A2.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A2.TFA.PSA.QZF.QM00Article: 3KXF421703V.A2.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 3,5 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A3.TFA.PSA.QZA.QM00Article: 3KXF421703V.A3.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A3.TFA.PSA.QZB.QM00Article: 3KXF421703V.A3.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A3.TFA.PSA.QZC.QM00Article: 3KXF421703V.A3.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A3.TFA.PSA.QZD.QM00Article: 3KXF421703V.A3.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A3.TFA.PSA.QZE.QM00Article: 3KXF421703V.A3.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421703V.A3.TFA.PSA.QZF.QM00Article: 3KXF421703V.A3.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 80; Analog Output: 4 ... 20 mA, Alarm < 22 mA; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V1.TFA.PSA.QZA.QM00Article: 3KXF421704V.V1.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V1.TFA.PSA.QZB.QM00Article: 3KXF421704V.V1.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V1.TFA.PSA.QZC.QM00Article: 3KXF421704V.V1.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V1.TFA.PSA.QZD.QM00Article: 3KXF421704V.V1.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V1.TFA.PSA.QZE.QM00Article: 3KXF421704V.V1.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V1.TFA.PSA.QZF.QM00Article: 3KXF421704V.V1.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 5 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V2.TFA.PSA.QZA.QM00Article: 3KXF421704V.V2.TFA.PSA.QZA.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(1) ... 60; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V2.TFA.PSA.QZB.QM00Article: 3KXF421704V.V2.TFA.PSA.QZB.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(8) ... 500; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V2.TFA.PSA.QZC.QM00Article: 3KXF421704V.V2.TFA.PSA.QZC.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(15) ... 900; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V2.TFA.PSA.QZD.QM00Article: 3KXF421704V.V2.TFA.PSA.QZD.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(25) ... 1500; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V2.TFA.PSA.QZE.QM00Article: 3KXF421704V.V2.TFA.PSA.QZE.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(50) ... 3000; Measuring range unit mass measurement: kg/hABB
3KXF421704V.V2.TFA.PSA.QZF.QM00Article: 3KXF421704V.V2.TFA.PSA.QZF.QM00 FMT700-P Compact Thermal Mass Flowmeter Sensor, standard characteristic curve, for air, test benches, nominal diameter DN 100; Analog Output: 0 ... 10 V; Operating temperature range: -25 ... 50°C; Operating pressure range: 0.6 ... 2.5 bar (abs); Measuring range mass measurement: 0(80) ... 5000; Measuring range unit mass measurement: kg/hABB